Benefits of Using Total Suspended Solids Test Equipment

Total suspended solids (TSS) are particles that are suspended in water and can be harmful to the Environment if not properly monitored and controlled. In order to measure the amount of TSS in water, specialized equipment known as total suspended solids test equipment is used. This equipment plays a crucial role in ensuring water quality and protecting aquatic ecosystems.

One of the key benefits of using total suspended solids test equipment is the ability to accurately measure the amount of TSS in water. This information is essential for determining the overall health of a body of water and identifying potential sources of pollution. By regularly monitoring TSS Levels, environmental scientists and water quality professionals can quickly identify any issues and take appropriate action to address them.

In addition to providing accurate measurements, total suspended solids test equipment is also easy to use and provides quick results. This makes it an ideal tool for field testing and monitoring, allowing for real-time data collection and analysis. This rapid feedback enables decision-makers to respond promptly to any changes in TSS levels and implement necessary measures to protect water quality.


Furthermore, total suspended solids test equipment is highly versatile and can be used in a variety of settings, including wastewater treatment plants, industrial facilities, and natural water bodies. This flexibility allows for comprehensive monitoring of TSS levels across different environments, ensuring that water quality standards are met and maintained.

Another benefit of using total suspended solids test equipment is the cost-effectiveness of the technology. By investing in reliable TSS Testing Equipment, organizations can avoid costly fines for non-compliance with water quality regulations. Additionally, regular monitoring of TSS levels can help prevent long-term damage to aquatic ecosystems, saving money on restoration efforts in the future.

Moreover, total suspended solids test equipment is essential for ensuring the effectiveness of water treatment processes. By accurately measuring TSS levels before and after treatment, operators can assess the efficiency of their systems and make necessary adjustments to improve performance. This proactive approach to water quality management helps to prevent contamination and protect public health.

Model No. CIT-8800 Inductive Conductivity / Concentration Online Controller
Measurement range Conductivity 0.00\\u03bcS/cm ~ 2000mS/cm
Concentration 1.NaOH\\uff0c\\uff080-15\\uff09% or\\uff0825-50\\uff09%\\uff1b
2.HNO3\\uff08note the Corrosion resistance of the sensor\\uff09\\uff080-25\\uff09% or\\uff0836-82\\uff09%\\uff1b
3.User-defined concentration curves.
TDS 0.00ppm~1000ppt
Temp. \\uff080.0 ~ 120.0\\uff09\\u2103
Resolution Conductivity 0.01\\u03bcS/cm
Concentration 0.01%
TDS 0.01ppm
Temp. 0.1\\u2103
Accuracy Conductivity 0\\u03bcS/cm ~1000\\u03bcS/cm \\u00b110\\u03bcS/cm
1 mS/cm~500 mS/cm \\u00b11.0%
500mS/cm~2000 mS/cm \\u00b11.0%
TDS 1.5 level
Temp. \\u00b10.5\\u2103
Temp. compensation element Pt1000
range \\uff080.0~120.0\\uff09\\u2103 linear compensation
\\uff084~20\\uff09mA Current output channels Double channels
features Isolated, adjustable, reversible, 4-20MA output, instruments/ transmitter mode.
Loop resistance 400\\u03a9\\uff08Max\\uff09\\uff0cDC 24V
Resolution \\u00b10.1mA
Control contact Channels Triple channels
Contact Photoelectric relay output
Programmable Programmable \\uff08 temperature \\u3001conductivity/concentration/TDS\\u3001timing\\uff09output
Features Could set temperature\\u3001conductivity/concentration/TDS\\u3001 timing NO/NC/ PID selection
Resistance load 50mA\\uff08Max\\uff09\\uff0cAC/DC 30V\\uff08Max\\uff09
Data communication RS485,MODBUS protocol
Power supply DC 24V\\u00b14V
Consumption \\uff1c5.5W
Working environment Temperature\\uff1a\\uff080~50\\uff09\\u2103 Relative Humidity\\uff1a\\u226485%RH(non- condensing )
Storage Temperature\\uff1a(-20~60)\\u2103 Relative Humidity\\uff1a\\u226485%RH(non- condensing)
Protection level IP65\\uff08with rear cover\\uff09
Outline dimension 96mm\\u00d796 mm\\u00d794mm (H\\u00d7W\\u00d7D)
Hole dimension 91mm\\u00d791mm(H\\u00d7W)
Installation Panel mounted , fast installation

Overall, total suspended solids test equipment is a valuable tool for monitoring and maintaining water quality. Its ability to provide accurate measurements, quick results, and cost-effective solutions makes it an essential component of environmental monitoring programs. By investing in TSS testing equipment, organizations can ensure the health and sustainability of water resources for future generations.